EEI
The EEI process computes EEI volumes by deriving Intercept (I) and Gradient (G) from the input angle stacks via per-sample linear regression of amplitude against sin²(θ) (Shuey two-term approximation: A(θ) = I + G·sin²(θ)). I and G are then rotated by a specified phase angle, and for each chi angle in the configured scan range, EEI(χ) = I·cos(χ) + G·sin(χ) is computed.
Create an EEI process
- In the Control Panel, open the Process tab.
- At the tab header, click the Add icon and select New Process.
- Search for or scroll down, and select EEI > Add.
- Type a name for the process and click OK and Close.
Configure EEI
- Angle stacks: Select two or more seismic angle stacks with known incidence angles (degrees). Near, mid, far, and ultra-far stacks are typical. All stacks must be from the same survey.
- Phase angle: Phase rotation applied to the derived Intercept and Gradient before computing EEI.
- Chi scan start / end / increment: The range of chi angles (degrees) over which the EEI chi scan gather is computed. End must be greater than start, and the increment must be at least 1°.
Output
Output volumes:
- EEI I: Phase-rotated intercept volume.
- EEI G: Phase-rotated gradient volume.
- EEI chi scan: A gather volume with one trace per chi angle across the configured chi scan range.
As a result of this process, the output volumes will be added in the Volume tab. To quickly open an output volume, right-click the process item in the Process tab and click Open the output volume. Vice versa, the process can be opened from the Volume tab directly — right-click the volume (indicated in italics) and click Open the Process.