Adding data to Spectral Analysis
The Spectral Analysis window generates frequency vs. amplitude spectra for 2D, 3D, gather and wavelet data.
Note: The Spectra Analysis tool does NOT operate on depth volumes. Convert depth data to time before analysis using Volume Resampling.
![](https://media.screensteps.com/image_assets/assets/001/862/731/original/13fd5f72-eb1f-41ed-9f7e-74ffcee1ae03.png)
To add data for spectra analysis:
-
Drag and drop
- From tabs in the Control Panel, drag volumes or wavelets into the Spectra Viewer panel.
-
Right-click menu: “Send to Spectra Analyser”
- In the Control Panel tab, right-click on a volume or wavelet and select “Send to Spectra Analyser”.
- The option is only available for data in the time-domain.
![](https://media.screensteps.com/image_assets/assets/001/927/399/original/e73c9fa7-ef94-47d3-bab0-4f991c5e7420.png)
The data for analysis is included in the Spectral Analysis tree.
Note: Because a wavelet product can contain several wavelets, wavelets are shown as folders.